Evaluation of Thermal Conditions in the GKB 2 Unimus Hall Using Temperature and Relative Humidity Parameters

Authors

  • Clarisa Isnaini Aulia Dewi Department of Architecture, Universitas Muhammadiyah Semarang, Indonesia
  • Mohhamad Kusyanto Department of Architecture, Universitas Muhammadiyah Semarang, Indonesia

Keywords:

thermal comfort, air temperature, relative humidity, GKB 2 hall, tropical climate

Abstract

This study aims to evaluate the thermal conditions in the hall on the 8th floor of GKB 2 Building, Muhammadiyah University of Semarang (Unimus) using temperature and relative humidity as the main indicators. The background of this study is the importance of thermal comfort in higher education spaces that directly impact the productivity and health of space users. Data collection was carried out periodically every hour from 06.00 to 18.00 at five observation points spread throughout the room. The measurement method used a digital hygrometer and supported by data analysis using Microsoft Excel to produce a graph of temperature and humidity fluctuations. The results show a general pattern that occurs in closed spaces in tropical climates, namely the temperature increases until midday and decreases in the afternoon, while relative humidity shows the opposite trend. This study provides an overview of the importance of ventilation management and space design strategies that are able to maintain thermal comfort throughout the day.

Author Biographies

Clarisa Isnaini Aulia Dewi, Department of Architecture, Universitas Muhammadiyah Semarang, Indonesia

First Author

Mohhamad Kusyanto, Department of Architecture, Universitas Muhammadiyah Semarang, Indonesia

Corresponding Author

References

R. Rosyadi, A. Yoseph, and P. Y. Nurlestya, “Kajian Standar Fasilitas Bangunan Pendidikan Tinggi,” vol. 9, no. 2, pp. 51–64, 2025.

W. Sanova et al., “JAUR ( Journal of Architecture and Urbanism Research ) Pengaruh Orientasi Bangunan terhadap Suhu Termal dan Kelembaban pada Unit Rusunawa Keudah di Banda Aceh The Effect of Building Orientation on Thermal Temperature and Humidity in Rusunawa Keudah Units ,” vol. 9, no. 1, pp. 37–48, 2025, doi: 10.31289/jaur.v9i1.14226.

V. V. Rondonuwu and P. H. Gosal, “331-667-1-Pb,” Media Matrasin, vol. 8, no. 2, pp. 131–140, 2011.

S. Muhammad Makruf et al., “Analisis Kelembaban Udara terhadap Tingginya Suhu di Sekaran Semarang,” J. Anal., vol. 4, no. 1, pp. 93–100, 2025, [Online]. Available: http://jurnalilmiah.org/journal/index.php/Analis

W. A. Oktavia, O. Setiani, T. Joko, F. K. Masyarakat, and U. Diponegoro, “LITERATURE REVIEW : KUALITAS UDARA DALAM RUANG SEBAGAI FAKTOR RISIKO KEJADIAN SICK BUILDING,” vol. 13, 2025.

M. Kusyanto, S. Triyadi, and S. Wonorahardjo, “Kualitas Ruang Masjid Berkubah yang Dibangun Masyarakat Secara Swadaya dari Aspek Kenyamanan Termal di Kabupaten Demak,” J. Lingkung. Binaan Indones., vol. 6, no. 3, pp. 134–143, 2017, doi: 10.32315/jlbi.6.3.178.

I. W. K. Samarta et al., “Studi Kenyamanan Termal Adaptif pada Ruang Ibadah Berbasis Komunitas,” in Prosiding Seminar Nasional Arsitektur Tropis UNUD, UNUD, 2021.

D. Rinaldi, “Space Quality of Two Indonesian Mosques: Architectural Strategies for Thermal Comfort,” in in Proceedings of ICA, 2021.

B. S. Nasional, “SNI 03-6572-2001, Tata cara perancangan sistem ventilasi dan pengkondisian udara pada bangunan gedung,” Jakarta, 2001.

N. J. Dingo, J. Kindangen, and P. Gosal, “Studi Pendinginan Pasif untuk Peningkatan Kenyamanan Ruang di Gedung Kantor Dinas Perumahan dan Kawasan Permukiman Kabupaten Minahasa Selatan,” J. Sains dan Teknol. SAINTEK, vol. 5, no. 1, pp. 158–169, 2023.

A. Hafidasari and W. Setiawan, “Analisis Efisiensi Energi menggunakan EDGE pada Gedung Baru Vokasi Universitas Brawijaya Kepanjen,” Pros. Semin. Ilm. …, pp. 33–43, 2025, [Online]. Available: https://proceedings.ums.ac.id/siar/article/view/5638%0Ahttps://proceedings.ums.ac.id/siar/article/download/5638/4926

M. M. Attaufiq, “Studi Hubungan Iklim Mikro terhadap Kondisi Ruang Belajar di Lingkungan Universitas Negeri Manado (Studi Kasus Pengaruh Suhu terhadap Kondisi Ruang Kelas),” JISIP (Jurnal Ilmu Sos. dan Pendidikan), vol. 7, no. 1, pp. 794–798, 2023, doi: 10.58258/jisip.v7i1.4111.

M. A. Hamdy, B. Hamzah, R. Wikantari, and R. Mulyadi, “Lingkungan dan Kenyamanan Termal Dalam Bangunan di Iklim Tropis Panas dan Lembab: Studi Literatur Sistematik,” JaS), vol. 3, no. 2, pp. 25–44, 2021, [Online]. Available: https://ejournalfakultasteknikunibos.id/index.php/jas/

R. Ahnaf and A. Bakar, “Terhadap Kenyamanan Psikologis Penghuni ( Studi Kasus : Rumah Bu Reny Palur ),” pp. 1163–1174, 2024.

D. Hendrawati, “AIR SEBAGAI ALAT PENGENDALI IKLIM MIKRO DALAM BANGUNAN Studi Kasus : Taman Sari Royal Heritage Spa, Hotel Sheraton Mustika Yogyakarta,” J. Tek. Sipil dan Perenc., vol. 18, no. 2, pp. 97–106, 2016, doi: 10.15294/jtsp.v18i2.7477.

Downloads

Published

2025-02-10

How to Cite

Dewi, C. I. A., & Kusyanto, M. (2025). Evaluation of Thermal Conditions in the GKB 2 Unimus Hall Using Temperature and Relative Humidity Parameters. Journal of Architecture and Urban Studies, 3(1), 7–14. Retrieved from https://jurnalnew.unimus.ac.id/index.php/terrace/article/view/987

Issue

Section

Article